HOBO Compressed Air Flow Meter Sensor

HOBO Compressed Air Flow Meter Sensor (1 - 80 SCFM, Nominal Pipe Size 1 inch)

Regular price£912.95 Inc VAT Price on application
£760.79 ex VAT @ 20%
/
Shipping calculated at checkout.
SKU T-CDI-5200-10S
  • In stock, ready to ship
  • Available to order
Effectively monitor compressed air systems with the CDI meter.
HousingCable
Compatible WithU12, ZW, UX120
MeasurementsCompressed Air Flow

The country of origin for this product is the United States.

T-CDI-5200-10ST-CDI-5400-20S
Measurement range 1 - 80 SCFM 40-600 SCFM (calibrated), 350 - 600 (uncalibrated)
Accuracy** 5% of reading plus 1% of full scale @ air temperatures 40 - 120F 5% of reading plus 1% of full scale @ air temperatures 40 - 120F; (5400 model extended range) 7% of reading from rated fule scale to 150% of calibrated range, @ air temperatures 40 - 120F
Medium** Compressed air, nitrogen Compressed air, nitrogen
Operating pressure** 30 to 170 psig for best accuracy. 200 psig max on Sch 40 steel 200 psig max on Sch 40 steel
Input power** 250 mA @ 18 - 24 VDC 250 mA @ 18 - 24 VDC
Output resistance** 400Ω max 400Ω max
Response time** 1 sec to 63% of final value 1 sec to 63% of final value
Output** 4 - 20mA or pulse 4 - 20mA or pulse
Display** 4-digit LED 4-digit LED
Ring material** Aluminum Aluminum
Size / Weight** 3.2x2.2x1.6 in / approx. 1.2 lb 3.2x2.2x1.6 in / approx. 1.4 lb

This item is priced on application. Tell us what you need and we'll send you a quote.

Or call us on 01243 558270

BUYING IN BULK, OR JUST WANT SOME HELPFUL ADVICE?

Call +44 (0)1243 558270, or fill out our contact form.

This product has been discontinued by Onset and is no longer available.

Please see our Compressed Air Flow Data Loggers range for current alternatives, or contact us for advice.

Effectively monitor compressed air systems with the CDI meter. This flow meter includes two probes, one warmer than the other. This arrangement calculates mass velocity based on heat requirements. Additionally, pipe area data is used to determine flow amounts.

Available in two versions:

  • T-CDI-5200-10S Output: 4-20mA representing 1 to 80 SCFM of air, Nominal Pipe Size: 1 inch
  • T-CDI-5400-20S Output: 4-20mA representing 40 to 600 SCFM of air, Nominal Pipe Size: 2 inches

Key Features

  • Easy to install
  • Digital display

Requirements for use with specific data loggers:

  • HOBO MX1100 series: a 4-20mA input cable (SD-MA-420) and external power provided by an AC adapter (AC-SENS-1)
  • HOBO U12, UX120-006M, or ZW series: a 4-20mA input cable (CABLE-4-20mA) and external power provided by an AC adapter (AC-SENS-1)
  • HOBO RX3000: an analogue input module (RXMOD-A1)
  • HOBO U30: an analogue input module (VIA)
  • HOBO H22: an analogue input module (S-FS-CVIA)

Recently viewed

Resources & Downloads