| Channel(s) | 1 |
|---|---|
| Sensor(s) | External Probe (Please select length) |
| Maximum Temperature | 100°C |
| Tolerance | ±0.5°C from -15° to 80°C |
| Battery Type | 2 AAA |
| Measurements | Temperature |
| Data Available By | Display, Online, Mobile App, WiFi, Email, Ethernet, Wireless (Bluetooth/RF) |
|
Logger |
|
|
Radio Power |
1 mW (0 dBm) |
|
Transmission Range |
Approximately 30.5 m (100 ft) line-of-sight |
|
Wireless Data Standard |
Bluetooth Low Energy (Bluetooth Smart) |
|
Logger Operating Range |
-30° to 70°C (-22° to 158°F), 0 to 95% RH (non-condensing) |
|
Logging Rate |
1 second to 18 hours |
|
Time Accuracy |
±1 minute per month at 25°C (77°F) |
|
Battery Type |
Two AAA 1.5 V alkaline or lithium batteries, user-replaceable |
|
Battery Life |
1 year, typical with logging interval of 1 minute. Faster logging intervals, remaining connected with the InTemp app, excessive report generation, numerous audible alarms, and paging all impact battery life. |
|
Memory |
128 KB (84,650 measurements, maximum) |
|
Full Memory Download Time |
Approximately 60 seconds; may take longer the farther the device is from the logger |
|
LCD |
LCD is visible from 0° to 50°C (32° to 122°F); the LCD may react slowly or go blank in temperatures outside this range |
|
Dimensions |
9.4 x 4.5 x 2.59 cm (3.7 x 1.77 x 1.02 inches) |
|
Weight |
90.2 g (3.18 oz) |
|
Environmental Rating |
IP54 |
|
CE |
The CE Marking identifies this product as complying with all relevant directives in the European Union (EU). |
|
External Temperature Probe |
|
|
Range |
-40° to 100°C (-40° to 212°F) |
|
Accuracy |
±0.5°C from -15° to 80°C (±0.9°F from 5° to 176°F) |
|
Resolution |
0.024°C at 25°C (0.04°F at 77°F) |
|
Drift |
<0.1°C (0.18°F) per year |
|
Response Time |
With 5 mL bottle: 10 minutes typical to 90% in air moving 1 m/s |
|
Cable Length |
2 or 4 meter (6.56 or 13.12 feet) flat ribbon cable |
|
Ambient Temperature Sensor |
|
|
Range |
-30° to 70°C (-22° to 158°F) |
|
Accuracy |
±0.5°C from -15° to 70°C (±0.9°F from 5° to 158°F) |
|
Resolution |
0.024°C at 25°C (0.04°F at 77°F) |
|
Drift |
<0.1°C (0.18°F) per year |
|
Response Time |
15 minutes typical to 90% in air moving 1 m/s |
This item is priced on application. Tell us what you need and we'll send you a quote.
Need a quick answer? Use live chat. For quotes or detailed requirements, send us the details and we'll reply by email.
Or call us on 01243 558270
Buying in volume, or just want some helpful advice?
Call +44 (0)1243 558270, or fill out our contact form.
InTemp CX402-Txxx (with Glycol Bottle) data loggers monitor temperatures in refrigerators, freezers and other temperature-controlled environments to comply with global GDP requirements. The loggers communicate wirelessly via Bluetooth to mobile devices.
Used in conjunction with the free InTemp app, you can easily view data, check logger status, set alarms, and create and share secure PDF reports for streamlined reporting and regulatory compliance. The CX402 features a built-in LCD display to view current and daily min and max temperatures, advanced audible and visual alarm capabilities for notification of temperature excursions, and an internal sensor for ambient temperature monitoring.
With the optional CX Internet Gateway device, you can get alert notifications via text and/or email of temperature excursions, and automatically download data from loggers within range of the device.
Models are available with a 2 or 4 metre external temperature probe attached to a Glycol bottle (if required) used to insulate the probe and delay thermal response times.
Key Features
- Easy-to-read display with current and daily min/max temperatures
- Audible and visual alarms for temperatures outside pre-set range
- Streamlined daily temperature checks simplify compliance
- Cost-effective – no subscription fees, free mobile app, and free cloud data storage
- Receive high/low temperature alerts via text/email with the optional CX Internet Gateway device
- Battery-powered to guard against local power loss
- Built to FDA, USP, EU, and WHO standards
- Integrates with mobile and cloud platforms for a 21 CFR Part 11 compliant solution
- Ideal for monitoring vaccines
- Spend less time on compliance and more time with patients.
Who is it For?
The InTemp CX402-Txxx data logger (with probe in glycol) is right for you if:
- You work for an organisation that’s required to primarily follow GDP/GMP, FDA, USP, and/or EU/CE guidelines for monitoring ambient to frozen temperatures
- Your organisation is a pharmaceutical manufacturer, third-party logistics company, Life Science/Biotech storage and transportation company, or other organisation looking to monitor temperature-sensitive goods.